The 8558A 8.5 digit multimeter offers 5 mega-samples-per-second high resolution digitizing for system automation in labs and manufacturing test environments.  Fluke’s new high-speed system design and the industry’s fastest direct digitizing capability enable significant throughput increases for many automated system applications that require a combination of highest speed and best accuracy.  The superb accuracy is delivered over a wide measurement range, over nine functions, with an intuitive user interface on a color display.
 
The 8558A shares the same platform as the fully loaded 8588A Reference Multimeter. The platform features a common intuitive user interface with easy-to-navigate menu structure for all configuration and matching SCPI-compliant commands for automated environment. The 8588A platform guarantees a minimum of 100,000 readings per second at 4.5 digits across GPIB, USBTMC or Ethernet, and an onboard data memory that can hold up to 15 million readings.
DC voltage
 
100 mV to 1000 V, (1050V max)
2.02x full scale
Maximum resolution: 1 nV
4.0 μV/V (95 %) 5.7 μV/V (99 %), 1 year
0.5 μV/V (95 %) 0.65 μV/V (99 %), 24 hour stability
0 to 10 s reading aperture (200 ns resolution)
 
DC current
 
10 uA to 2 A (8558A)
2.02x full scale
Maximum resolution: 1 pA
9 μA/A (95 %), 12 μA/V (99 %), 1 year
0 ns to 100 s reading aperture
 
AC voltage
 
10 mV to 1000 V, 1 Hz to 10 MHz, (1050 Vrms max)
2.02x full scale Vpp, 1.2x full scale Vrms
Maximum resolution: 1 nV
80 μV/V (95 %), 103 μV/V (99 %), 1 year
 
AC current
 
10 uA to 30 A (8588A only; 2 A for 8558A)
2.02x full scale Vpp, 1 Hz to 100 kHz 1.2x full scale Vrms
Maximum resolution: 1 pA
300 μA/A (95 %), 387 μA/V (99 %), 1 year
 
Resistance
 
1Ω to 10 GΩ (20 GΩ max)
2.02x full scale
Maximum resolution: 10 nΩ
10 μΩ/Ω (95 %), 13 μΩ/Ω (99 %), 1 year
Low current mode, high voltage mode and Tru Ohms™
 
Digitize V
 
100 mV to 1000 V, (1050 V max)
2.02x full scale
Maximum resolution: 18 bits
5 mega-samples per second sample rate
Up to 20 MHz bandwidth
 
Digitize I
 
10 μA to 30 A (8588A only; 2 A for 8558A)
2.02x full scale
Maximum resolution: 18 bits
5 mega-samples per second sample rate
Up to 4 MHz bandwidth
 
Frequency or period
 
Voltage, up to 10 MHz
Current, up to 100 kHz
Frequency up to 100 MHz on BNC
0.5 μHz/Hz, 1 year
 
Capacitance
 
1 nF to 100 mF
400 μF/F, 1 year
 
Temperature
 
PRT and thermocouple
5 mK, 1 year
 
RF power
 
Rhode & Schwarz NRP series DC I and AC I external shunt
 
DC I and AC I external shunt
 
A40B and any other external shunt
 
Reading speed
 
1 reading /s @ 8.5 digit into memory
100,000 readings /s @ 4.5 digit into memory
Up to 500,000 readings /s into volatile memory in digitize V and I
Up to 500,000 readings/s transfer through USB in binary format
 
Measurement memory
 
15 million readings
7.5 million readings with time stamp
 
GPIB, USBTMC, Ethernet
 
Native SCPI compliant remote commands
8508A and 3458A emulation mode
Fully support MET/CAL™ calibration procedures library in Fluke 8508A emulation
IVI driver
USB thumb drive for convenient data transfer in .csv format
 
Trigger mechanisms
 
Manual trigger
External BNC Trig In and Trig Out
Internal or level trigger
Timer trigger
Epoch trigger
Line trigger
BUS trigger
 
  8558A 8588A
DC voltage 100 mV – 1000 V 100 mV – 1000 V
AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
DC current 10 uA – 2 A 10 uA – 30 A
Digitize V 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
Digitize I
10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
Capacitance No 1 nF – 100 mF
RF power No R&S NRP Series
Ext. dc current and ac current No A40B current shunt and other shunts
Graphical display Yes Yes
Visual Connection Management ® Yes Yes
Programmable front/rear input switching Yes Yes
Ratio ohms, voltage Yes Yes
External 10 MHz ref clock, 50 Ω/Hi-Z Yes Yes
A40B and other shunt asset management No Yes
GPIB 488.2, Ethernet, USB TMC Yes Yes
SCPI command compatibility Yes Yes
3458A emulation, 8508A emulation Yes Yes
Memory 15 million 15 million
Level and other trigger Yes Yes
FFT onboard No Yes
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

 

Model Name Description
8558A
8.5 Digit Multimeter
 
Includes:
 
Meter
8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB
8588A
Reference Multimeter
 
Includes:
 
Meter
8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB

 

Accessory Description
Y8588 Rack Mount Kit (2U – 3.5 in)
Y8588S Slide Rack Mount Kit
8588A-LEAD
Comprehensive Measurement Lead Kit
Includes:
1x 8588A-LEAD KIT-OSP
1x 1 m screen 322/0.1 copper (30 Amp Rating) with 6 mm gold plated copper spade terminals
4X 8588A-LEAD/THERMAL
2x locking adapter 4 mm binding post to safety
8588A-SHORT
8588A-SHORT 4-Way Shorting PCB
8588A-LEAD/THERMAL Low Thermal Lead Kit
8588A-7000K Cal Kit with 1 Gohm Standard and Connecting Leads
96000SNS Additional Power Sensor
8588A/CASE Transit Case