Fluke 369 FC Leakage Current Clamp Meters
The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.
Measurement function | Alternating current | |
AC ampere range | 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A | |
Range selection |
mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
|
|
Range / Resolution | 3 mA¹ / 0.001 mA | |
30 mA / 0.01 mA | ||
300 mA / 0.1 mA | ||
3 A / 0.001 A | ||
30 A / 0.01 A | ||
60 A / 0.1 A | ||
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² |
3 mA – 30 A
60 A
|
1% + 5 digits
2% + 5 digits
|
Frequency | 40 Hz to 1 kHz | |
Crest Factor | 3 |
Display (LCD) | Digital readout: 3300 count |
Display refresh rate | 4 times / sec |
Maximum conductor diameter | 61 mm |
Dimensions | 257 x 116 x 46 mm |
Weight | 600 g |
Battery | 2 AA, IEC LR6, NEDA 15A, alkaline |
Battery life | Expected battery life, without using backlight and spotlight, is more than 150 hours |
Automatic shut-down | Meter automatically shuts down after 15 minutes of inactivity |
Safety and Environmental Specifications:
General safety | IEC 61010-1: Pollution Degree 2 |
Measurement safety | IEC 61010-2-032: CAT III 600 V / CAT IV 300 V |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Operating humidity | Non-condensing (<10 °C) |
90% relative humidity (10 °C to 30 °C) | |
75% relative humidity (30 °C to 40 °C) | |
45% relative humidity (40 °C to 50 °C) | |
Protection class | IEC 60529: IP30 (jaw closed) |
Operating altitude | 2000 m |
Storage altitude | 12000 m |
Current sensor action category | IEC 61557-13: Class 1, ≤100 A / m |
International:
IEC 61326-1 | Industrial Electromagnetic Environment |
CISPR 11 | Group 1 Class B |
Group 1 | Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential. |
Class B |
Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
|
Class A |
This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
|