Simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results.
 
The Fluke MDA 510 and MDA 550 Motor-Drive Analyzers save time and eliminate the hassle of setting up complex measurements, while simplifying the troubleshooting process for variable frequency drives. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, the MDA-500 Series has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence.
 
The MDA-510 and MDA-550 are the ideal portable motor-drive analysis test tools and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.
 
Measure key motor-drive parameters including voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance and harmonics (MDA-550), voltage modulation, and motor shaft voltage discharges (MDA-550).
Perform extended harmonics measurements to identify the effects of low and high order harmonics on your electrical power system.
Conduct guided measurements for motor-drive input, DC bus, drive output, motor input and shaft measurements (MDA-550) with graphical step-by-step voltage and current connection diagrams.
Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure.
Create reports quickly and easily that are perfect for documenting troubleshooting and collaborative work with others.
Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems.
Key features
  • Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever
  • Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration
  • Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports
Measurement Function:
 
DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 999 counts
Accuracy at 4 s to 10 us/div ±(3 % + 6 counts)

AC voltage (V ac)

Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 999 counts
50 Hz ±(3 % + 10 counts) - 0.6 %
60 Hz ±(3 % + 10 counts) - 0.4 %
60 Hz to 20 kHz ±(4 % + 15 counts)
20 kHz to 1 MHz ±(6 % + 20 counts)
1 MHz to 25 MHz ±(10 % + 20 counts)

True-rms voltage (V ac+dc)

Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 1 mV
Full scale reading 1100 counts
DC to 60 Hz ±(3 % + 10 counts)
60 Hz to 20 kHz ±(4 % + 15 counts)
20 kHz to 1 MHz ±(6 % + 20 counts)
1 MHz to 25 MHz ±(10 % + 20 counts)

PWM voltage (V pwm)

Purpose To measure on pulse width modulated signals, like motor drive inverter outputs
Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy As Vac+dc for sinewave signals

Peak voltage (V peak)

Modes Max peak, min peak, or pk-to-pk
Maximum voltage with 10:1 or 100:1 probe 1000 V
Maximum resolution with 10:1 or 100:1 probe 10 mV

Accuracy

Max peak, min peak ±0.2 division
Pk-to-pk ±0.4 division
Full scale reading 800 counts

General Specification

Current (AMP) with current clamp

Ranges Same as V ac, Vac+dc or V peak
Scale Factors 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Accuracy Same as Vac, Vac+dc or V peak (add current clamp accuracy)

Frequency (Hz)

Range 1.000 Hz to 500 MHz
Full scale reading 999 counts
Accuracy ±(0.5 % + 2 counts)

Voltage/Herz ratio (V/Hz)

Purpose To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives
Accuracy % Vrms + % Hz

Voltage unbalance drive input

Purpose To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
Accuracy Indicative percentage based on Vac+dc values

Voltage unbalance drive output and motor input

Purpose To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages
Accuracy Indicative percentage based on V PWM values

Current unbalance drive input

Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values
Accuracy Indicative percentage based on Aac+dc values

Current unbalance drive output and motor input

Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values
Accuracy Indicative percentage based on A ac values

Rise and fall time

Readings Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot
Accuracy As oscilloscope accuracy

Harmonics and spectrum

Harmonics DC to 51st
Spectrum ranges 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation)

Shaft voltage

Events / second Indicative percentage based on rise and fall time (Impulse discharges) measurements

Report data capture

Number of screens Typical 50 screens can be saved in reports (depends on compression ratio)
Transfer to PC Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool

Probe settings

Voltage probe 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1
Current clamp 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Shaft voltage probe
1:1, 10:1, 100:1
 

 

Models: Fluke MDA-510 and MDA-550 Motor Drive Analyzers
 
Fluke MDA-550Motor drive analyzer, 4 channel, 500 MHz with motor shaft and harmonics
 
Includes:
  • 1x BP 291 li-ion battery pack
  • 1x BC190 charger/power adapter
  • 3x VPS 100:1 high voltage probes with alligator clips
  • 1x VPS410-II-R 10:1 500MHz voltage probe
  • 3x i400s ac current clamp
  • 1x C1740 carrying case
  • 1x 2 GB USB drive with manuals and FlukeView™ 2 software
  • 1x SVS-500 shaft voltage set (3x brush, probe holder, two-piece extension rod and magnetic base)