The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.
The 1586A Super-DAQ collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.
When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best benchtop reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration drywell or bath and Automated Sensor Test routines are run.
General Specifications |
|
Mains Voltage |
100 V Setting: 90 V to 110 V |
Frequency |
47 Hz to 440 Hz |
Power Consumption |
36 VA peak (24 W average) |
Environment Temperature |
Operating: 0 °C to 50 °C |
Relative Humidity (non-condensing) |
Operating: 0 °C to 30 °C <80 %; |
Altitude |
Operating: 2,000 m |
Vibration and Shock |
Complies with MIL-PRF-28800F Class 3 |
Channel Capacity |
Total analog channels: 45 |
Channel Input Connector Types |
1586A Channel 001 (front panel): gold
pins, bare wire, spade lugs, banana plugs |
Input Protection |
50 V all functions, terminals and
ranges |
Math Channels |
Number of channels: 20 |
Triggers |
interval, external (trigger input),
alarm, remote (bus), manual, automated test |
Memory |
Scan data RAM: 75,000 readings
with timestamp, Data/Setup flash memory: 20 MB |
USB Host Port |
Connector type: Type A |
USB Device Port |
Connector type: Type B |
LAN |
Function: Control and data transfer |
RS-232 |
Connector: D-sub 9 pin (DE-9) |
Dimensions |
Height: 150 mm |
Conformity |
CE, CSA, IEC 61010 3rd ed. |
Model Name |
Description |
1586A/1DS |
Super-DAQ Precision Temperature
Scanner, 1 DAQ-STAQ Multiplexer |
1586A/1DS/C |
Super-DAQ Precision Temperature
Scanner, 1 DAQ-STAQ Multiplexer, Accredited Calibration |
1586A/2DS |
Super-DAQ Precision Temperature
Scanner, 2 DAQ-STAQ Multiplexers |
1586A/2DS/C |
Super-DAQ Precision Temperature
Scanner, 2 DAQ-STAQ Multiplexers, Accredited Calibration |
1586A/DS-HC |
Super-DAQ Precision Temperature
Scanner, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer |
1586A/DSHC/C |
Super-DAQ Precision Temperature
Scanner, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer, Accredited
Calibration |
1586A/1HC |
Super-DAQ Precision Temperature
Scanner, 1 High-Capacity Module |
1586A/1HC/C |
Super-DAQ Precision Temperature
Scanner, 1 HIgh-Capacity Module, Accredited Calibration |
1586A/2HC |
Super-DAQ Precision Temperature
Scanner, 2 High-Capacity Modules |
1586A/2HC/C |
Super-DAQ Precision Temperature
Scanner, 2 High-Capacity Modules, Accredited Calibration |
2680A-APSW v6.0 |
Fluke DAQ 6.0 Application Software
for Fluke data acquisition products. |
|
Click here for more information |
TQSOFT-IQ/OQ |
TQSoft Pharma Process Analysis and
Validation Software |
TQAERO |
TQAero Furnace Validation Software |
VAL-BNDR-TQS |
Validation Reference Binder |