The new gold standard in electrical calibration
Since 1988, the 5700A family has set the standard for multifunction calibrator performance in calibration laboratories around the world.
Now the time has come to advance this best-in-class calibrator, taking advantage of twenty-first century technology and usability.
The calibrator for those who demand the best
The 5730A is designed for calibration professionals who require the most accurate dc/lf signals available in a multifunction calibrator, as well as those who simply want the best calibrator available. Metrologists in national laboratories, the military, third party calibration laboratories, and corporate users with high-end workload will value the performance and reliability of the 5730A. All 5730A calibrators are traceable to international standards and are produced in the factory with ISO/IEC 17025 accredited calibrations. Specifications are stated to the standard Fluke Calibration 99 % confidence level (as well as 95 % confidence level) to support easy measurement comparisons according to international quality standards. Specifications are absolute and include the uncertainty of the calibration standards used. No additional analysis is required.
General Specifications |
|
Warm up time |
Twice the time since last warmed up,
to a maximum of 30 minutes |
Settling time |
Less than 5 seconds for all functions
and ranges except as noted |
Standard interfaces |
IEEE-488 (GPIB), RS-232, USB 2.0
Device, Ethernet, 5725A, 52120A, phase lock in (BNC), phase reference out
(BNC) |
Temperature performance |
Operating: |
|
Calibration: |
|
Storage: |
Operating altitude |
2000 m maximum |
Relative humidity |
Operating: |
|
Storage: |
Safety |
IEC 61010-1: 300 V CAT II, Pollution
Degree 2 |
Analog low isolation |
20 V |
Electromagnetic environment |
IEC 61326-1: Controlled |
Line power |
47 Hz to 63 Hz; ±10% 100 V,
110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V |
Power consumption |
300 VA |
Dimensions |
Height:: |
|
Width:: |
|
Depth: |
Weight |
27 kg: |
|
|
Absolute uncertainty definition |
5730A uncertainty specifications
include stability, temperature coefficient, linearity, load regulation, and
the traceability of the external standards used for calibration. You do not
need to add anything to determine the total uncertainty of your calibrator
for the temperature range indicated |
Specification confidence interval |
99% and 95% |
Model Name |
Description |
5730A |
Multifunction Calibrator |
5730A/03 |
Multifunction Calibrator with 30 MHz
Wideband AC Voltage Option |
5730A/05 |
Multifunction Calibrator with 50 MHz
Wideband AC Voltage Option |
5730A/S |
Multifunction Calibrator with No
Front Panel USB Port |
52120A |
Transconductance Amplifier |
5725A |
Amplifier |
MET/CAL/TEAM |
Software, MET/CAL w/MET/TEAM |