Product overview: Fluke 353 True RMS 2000 A Clamp Meter
Versatile and rugged tool for applications with high currents
Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.
Key features
Reliably handle a wide range of high-current applications with 2000 A AC plus DC true-rms, 1400 A ac, and 2000 A DC
The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A large backlit display allows for easy visibility in low-lit areas
Use the display hold feature to capture readings even when the display cannot be viewed
Use the low-pass filter to smooth out noisy loads and stabilize readings
Specifications: Fluke 353 True RMS
2000 A Clamp Meter |
|
Electrical Specifications |
|
Current measurement DC and AC 10 Hz
to 100 Hz |
Range |
|
Resolution |
|
Accuracy |
|
|
|
Trigger level for Inrush |
|
Trigger level for Hz filter OFF |
|
Trigger level for Hz filter ON |
Crest Factor (50/60 Hz) |
Range 40 A / 400 A / 2000 A / 1400 AC
RMS |
Current measurement AC 100.1 Hz to 1
kHz |
Range |
|
Resolution |
|
Accuracy |
|
Trigger level for Inrush |
|
Trigger level for Hz filter OFF |
|
Trigger level for Hz filter ON |
Frequency measurement |
Measurement range |
|
Resolution |
|
Accuracy – 5.0 Hz to 100 Hz |
|
Accuracy – 100.1 Hz to 1 kHz |
|
Trigger level |
General Specifications |
|
Batteries |
Six 1.5 V AA NEDA 15 A or IEC LR6 |
Battery life (with typical usage,
backlight off) |
100 hours |
Test leads |
Rated to 1000 V |
Weight |
.814 kg (1.8 lb) |
Jaw size |
58 mm (2.28 in) |
Dimensions (L x W x D) |
300 x 98 x 52 mm (12 x 3.75 x 2 in) |
Safety rating |
IEC 61010-2-032, 600 V CAT IV, 1000 V
CAT III |
Environmental Specifications |
|
Operating temperature |
32°F to +122°F (0°C to +50°C) |
Storage temperature |
-4°F to 140°F (-20°C to +60°C) |
Operating humidity |
0 to 95% (non-condensing) |
Operating altitude |
2000 m |
Storage altitude |
10,000 m |
IP rating |
42 (indoor use only) |
Drop test requirements |
1 m |
EMI, RFI, EMC |
FCC part 15, IEC/EN 61326-1:1997
class B |
|
IEC/EN 61326:1997 3V/m, performance
criteria B, EN61325 |
Temperature coefficients |
Current |
|
Voltage |
Models: Fluke 353 True RMS 2000 A Clamp Meter
Fluke 353Fluke 353 True RMS 2000 A Clamp Meter
Includes:
353 clamp meter
C43 Soft carrying case
6 AA batteries
User manual
3 year warranty