Product overview: Fluke 369 FC Leakage Current Clamp Meter
Reduce downtime – Find leakage currents without taking equipment offline.
The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.
The Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamps jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.
The 369 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industrys largest system of software and more than 40 wireless test tools — the 369 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures
Key features
True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
61 mm jaw opening
Highest resolution of 1 μA, measure up to 60 A
Selectable filter function removes unwanted noise
Max/Min/Average readings and hold function
Forward-facing LED worklight for use in dark wiring cabinets
Backlit display auto backlight off and auto power off for extended battery life
CAT III 600V safety rating
Specifications: Fluke 369 FC Leakage
Current Clamp Meter |
||
Electrical Specifications |
||
Measurement function |
Alternating current |
|
AC ampere range |
3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A |
|
Range selection |
mA / A: manual selection |
|
Range / Resolution |
3 mA/ 0.001 mA |
|
|
30 mA / 0.01 mA |
|
|
300 mA / 0.1 mA |
|
|
3 A / 0.001 A |
|
|
30 A / 0.01 A |
|
|
60 A / 0.1 A |
|
Accuracy – filter activated (40 to 70
Hz), filter off (40 to 1 kHz)² |
3 mA – 30 A |
1% plus 5 digits |
|
60 A |
2% plus 5 digits |
Frequency |
40 Hz to 1 kHz |
|
Crest Factor |
3 |
|
Physical |
|
|
Display (LCD) |
Digital readout: 3300 count |
|
Display refresh rate |
4 times / sec |
|
Maximum conductor diameter |
61 mm |
|
Dimensions |
257 x 116 x 46 mm |
|
Weight |
600 g |
|
Battery |
2 AA, IEC LR6, NEDA 15A, alkaline |
|
Battery life |
Expected battery life, without using
backlight and spotlight, is more than 150 hours |
|
Automatic shut-down |
Meter automatically shuts down after
15 minutes of inactivity |
|
Safety and Environmental
Specifications |
||
General safety |
IEC 61010-1: Pollution Degree 2 |
|
Measurement safety |
IEC 61010-2-032: CAT III 600 V / CAT
IV 300 V |
|
Operating temperature |
-10 °C to plus 50 °C |
|
Storage temperature |
-40 °C to plus 60 °C |
|
Operating humidity |
Non-condensing (<10 °C) |
|
|
90% relative humidity (10 °C to 30
°C) |
|
|
75% relative humidity (30 °C to 40
°C) |
|
|
45% relative humidity (40 °C to 50
°C) |
|
Protection class |
IEC 60529: IP30 (jaw closed) |
|
Operating altitude |
2000 m |
|
Storage altitude |
12000 m |
|
Current sensor action category |
IEC 61557-13: Class 1, ≤100 A /
m |
|
Electromagnetic compatibility (EMC) |
||
International |
|
|
IEC 61326-1 |
Industrial Electromagnetic
Environment |
|
CISPR 11 |
Group 1 Class B |
|
Group 1 |
Generated inside the equipment and /
or use radio frequency energy associated with conducting the energy for the
devices own internal functions is essential. |
|
Class B |
Equipment for home appliances and
residential buildings directly connected to a low voltage power supply
network equipment. When this device is connected to a test object, it may
exceed the emission levels produced by CISPR 11 requirements. |
|
|
Korea (KCC): Class A Equipment
(Industrial Broadcasting & Communication Equipment) |
|
Class A |
This product meets the requirements
of industrial electromagnetic equipment, vendors or users should be aware of
this. This device is intended for use in a commercial environment, instead of
the home environment. |
|
|
USA (FCC): 47 CFR 15 subpart B. This
product is considered an exempt device per clause 15.103. |
Models: Fluke 369 FC Leakage Current Clamp Meter
Fluke 369 FCFluke 369 FC Leakage Current Clamp Meter
Includes:
Leakage Clamp Meter
Soft case
Safety Manual
Batteries: 2 AA