The 5322A Electrical Tester Calibrator helps calibration technicians comply with new regulatory standards up to four times faster than with traditional manual, multiple-product methods.The 5322A replaces the 5320A Electrical Tester Calibrator.
The 5322A calibrator facilitates compliance with exacting international standards such as the United Kingdom’s BS7671 17th Edition, IEC/EN Standards, Australia and New Zealand’s AS/NZS 3000 and Chinese verification/calibration regulations for various electrical testers.
The 5322A combines many functions into a single instrument, replacing discrete resistors, decade boxes and other custom solutions commonly used to calibrate electrical testers. This single-box solution speeds and simplifies calibration because users only need to learn, operate and maintain one calibrator rather than multiple instruments. And while it’s difficult to automate multiple instruments, the 5322A can be automated with MET/CAL® Calibration Software—further increasing speed and throughput.
Calibrate all major types of electrical safety testers with just one calibrator. The 5322A calibrates all major categories of electrical safety testers. The benefits of this calibrator are best described by the key functionality it brings to calibrating the individual workloads.
Key features and benefits
General specifications
pecifications confidence level |
99% |
Specifications interval |
1 year |
Power line |
115/230 V ac (50/60 Hz) +10 % / -14 %, with the maximum voltage
difference between neutral and protective earth not exceeding 15 V. Operation
with power line between -10 % and -14 % has limitations in burden current for
voltage outputs. See AC/DC Voltage Calibrator (VLC option) below. |
Power consumption |
1250 VA maximum |
Fuse protection |
AC mains input: 2 A, 250 V for 230 V, time delay (T2L250 V – 5 mm x
20 mm) 4 A, 250 V for 115 V, time delay (T4L250 V – 5 mm x 20 mm) RCD input: 3.15 A, 250 V, fast (F3.15H250 V – 5 mm x 20 mm) Meter amps (A) input: 20 A, 500 V, time delay (F20H500 V – 6.3 mm x
32 mm) Loop/Line impedance input: 4 A, 500 V, time delay (T4H500 V – 6.3 mm
x 32 mm) Leakage current input: 100 mA, 250 V, fast (F100 mL250 V – 5 mm x 20
mm) |
Environment
Warm-up time |
15 minutes |
Temperature performance |
Operating temperature: 18 °C to 28 °C Calibration temperature (tcal): 23 °C Temperature coefficient for temperatures outside of tcal ± 5 °C is
0.1 / °C of the specification, for temperatures between 5 °C to 40 °C. Storage temperature : -10 °C to 50 °C Storage recovery time: Typically <24 hours at operating
temperature. |
Relative humidity (operating) |
<80 % to 28 °C (resistance outputs >10 GΩ specified for <70
% to 28 °C) |
Relative humidity (storage) |
90 % non-condensing 0 °C to 50 °C |
Altitude |
Operating: 3050 m (10 000 ft) Storage: 12 200 m (40 000 ft) |
Accessories common to all models:
Model Name | Description |
5322A | Multifunction Electrical Tester Calibrator with 1.5 kV Resistance |
5322A/5 | Multifunction Electrical Tester Calibrator with 5 kV High Voltage Resistance Outputs |
5322A/VLC | Calibrator with 1.5 kV Resistance, 600 V Source, Voltage Loop Compensation |
5322A/40 | Calibrator with 1.5 kV Resistance and 40 kV Probe |
5322A/5/VLC | Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation |
22A/VLC/40 | Calibrator with 1.5 kV Resistance, 600 V Source, Voltage loop Compensation and 40 kV Probe |
5322A/5/40 | Calibrator with 5 kV Resistance, and 40 kV Probe |
5322A/5/VLC/40 | Calibrator with 5 kV Resistance, 600 V Source, Voltage Loop Compensation and 40 kV Probe |
Accessory | Description |
5322A-LOAD | High Voltage Resistor Load for 5322A |
Y5320A | Rack Mount Kit for 5322A – Sliding |
5322A/CASE | Transit Case for 5322A (without 5322A-LOAD) |