The new Fluke TiX885, TiX880, TiX875, and TiX870 thermal cameras, with 640 x 480 resolution, provide superior image quality needed for experimental R&D applications. With the help of Super Resolution technology, the high-end TiX885 and TiX880 cameras can produce images with a resolution of 1280 x 960 pixels. Capture images while moving or use the camera for measuring fast-changing temperatures with a frame rate of up to 30 Hz.
Key features
640 x 480 resolution infrared camera with large 5.5-inch OLED responsive touch screen.
Provides temperature measurements from -40 °C to +1200 °C (-40 °F to 2192 °F)
Up to 1 to 35x continuous digital zoom
SmartView IR software to view, optimize, annotate, and analyze infrared images, and generate fully customizable professional reports.
| TiX870 | TiX875 | TiX880 | TiX885 | |
| Detector | ||||
| IR Resolution | 640 × 480 | |||
| SuperResolution | - | - | Enhanced to 1280 × 960 pixels | Enhanced to 1280 × 960 pixels |
| Thermal Sensitivity* (* Under best case scenario) | <35 mK @ 30 °C | <30 mK @ 30 °C | <25 mK @ 30 °C | |
| Field of View (FOV) | 25° × 19° | |||
| Spatial Resolution (IFOV) | 0.68 mRad | |||
| Digital Zoom | 1 to 25x | 1 to 35x | ||
| Detector Type | Focal Plane Array (FPA), Uncooled Infrared Detector | |||
| Spectral Response | 8 to 14 um | |||
| Lens Aperture | F 1.0 | |||
| Lens Recognition | Auto | |||
| Minimum Focus Distance | 0.2 m | |||
| Focus System | Auto/Manual | |||
| Frame Rate | 9 Hz | 30 Hz | 9 Hz | 30 Hz |
| Measurement and Analysis | ||||
| Temperature Range | -40 °C to 700 °C | -40 °C to 700 °C | -40 °C to 1200 °C | -40 °C to 1200 °C |
| Temperature Measurement Range | -40 °C to 150 °C | -40 °C to 150 °C | -40 °C to 150 °C | -40 °C to 150 °C |
| 0 °C to 350 °C | 0 °C to 350 °C | 0 °C to 350 °C | 0 °C to 350 °C | |
| 0 °C to 700 °C | 0 °C to 700 °C | 0 °C to 700 °C | 0 °C to 700 °C | |
| 300 °C to 1200 °C | 300 °C to 1200 °C | |||
| Temperature Accuracy | ±2 °C or ±2% of reading, whichever is greater (normal temperature, 23 °C typical) | |||
| High/Low-Temperature Capture | Yes | |||
| Reference Temperature Compensation | Yes. The full-screen and measurement mark temperature are displayed as the difference between the actual temperature and the fixed temperature | |||
| Automatic Temperature Difference Calculation | Calculation of the difference between measurement marks or between a measurement mark and the fixed reference temperature | |||
| Custom Temperature Measurement Point | 10 points | 20 points | 10 points | 20 points |
| Custom Temperature Measurement Area | 10 areas (circle or rectangle) | 20 areas (circle or rectangle) | 10 areas (circle or rectangle) | 20 areas (circle or rectangle) |
| Line Temperature Measurement | 10 lines | 20 lines | 10 lines | 20 lines |
| Temperature Measurement Methods | The highest and lowest temperature can be set within an area, and the highest/lowest temperature point can be automatically located | |||
| Correction Settings | Emissivity, Reflected Temperature, Humidity, Ambient Temperature, Test Distance, Transmittance | |||
| Full-Screen Emissivity Correction | 0.01 to 1.00, built-in common material emissivity table | |||
| Areal Emissivity Correction | Yes | |||
| Analysis in the Imager | Yes | |||
| Analysis Software | SmartView IR | |||
| Supported Languages | Simplified Chinese/English | |||
| Image Display | ||||
| Display | OLED touchscreen, 170° visual range | |||
| Display Size | 5.5 inches | |||
| Display Contrast | 100000:1 | |||
| Display Resolution | 1920 × 1080 pixels, 1080P UHD display | |||
| Digital Image Enhancement | Yes | |||
| Settings for On-Screen Display (OSD) | Yes. Users can define OSD, such as the maximum, minimum, average temperature; full-screen emissivity and reflected temperature | |||
| Settings for Information Display of Temperature Measurement Mark | Yes. Each temperature measurement mark can be set separately, such as emissivity | |||
| Built-in Digital Camera | 5.0 MP | |||
| LED Torch/Flashlight | Yes | |||
| Picture-in-Picture (PIP) | Yes | |||
| Color Palettes | 15 | |||
| Manual Span Adjustment | Yes | |||
| Auto Span Adjustment | Yes | |||
| Minimum Temperature Span (in manual mode) | 2 °C | |||
| Minimum Temperature Span (in auto mode) | 4 °C | |||
| Video | ||||
| Fully-Radiometric Infrared Video Recording | - | Recorded to the Imager and PC | - | Recorded to the Imager and PC |
| Fully-Radiometric Infrared Video Recording (Frame Rate Adjustable) | - | 1 to 12 Hz | - | 1 to 12 Hz |
| Fully-Radiometric Infrared Video Streaming | - | USB 2.0 | - | USB 2.0 |
| Non-radiometric Infrared Video Streaming (HDMI output) | Transmission via HDMI | |||
| Auto Capture | Customized frame rate or interval | |||
| Professional Functions | ||||
| Color Alarm (Isotherm) | Yes. High temperature alarm, low temperature alarm | |||
| QR Code Recognition | QR code supported | - | QR code supported | QR code supported |
| Voice Annotation | Yes. 200 s of voice annotation for every image | |||
| Text Annotation | Yes | |||
| Visible Light Image Association Technology | Yes | |||
| Storage and Transfer | ||||
| Image Viewing | Thumbnail view navigation and view selection | |||
| Storage Medium | Built-in 16G flash + 128 high-speed SD card | |||
| SD Card | Included | |||
| IR Image File Format | Standard JPEG, including measurement data, which meets the data format verification requirements of the State Grid for Infrared Imagers | |||
| Video File Format | - | .mp4, .IS5 | - | .mp4, .IS5 |
| Visible Image File Format | Standard JPEG format | |||
| Audio | Yes | |||
| Transfer Interface | USB Type-C, HDMI, SD card, Bluetooth | |||
| Bluetooth Transfer | Yes. The saved files can be transferred to a PC via Bluetooth. | |||
| GPS | Yes | - | Yes | Yes |
| Remote Display Viewing | Yes. View thermal video streaming on a PC or a display terminal by connecting to the SmartView IR software on a PC via USB, or connecting to a display terminal via HDMI | |||
| Remote Control Operation | Yes. Through the SmartView IR Software | |||
| USB | USB 2.0 | |||
| Antenna | Internal | |||
| Bluetooth Transfer | ||||
| Frequency | 2400 MHz to 2483.5 MHz | |||
| Output Power | <100 mW | |||
| Laser | ||||
| Laser Standard | IEC 60825-1, Class 2, 650nm, <1mW | |||
| Power and Environment | ||||
| Battery Type | Li-ion batteries (3 pcs) | |||
| Battery Life | > 3.5 hrs for continuous use @ ambient temperature of 25 °C | |||
| Weight | 1550 g (with battery) | |||
| Dimensions | 148 mm × 204 mm × 86 mm | |||
| Certification Standards | IEC 61326-1:Industrial Electromagnetic Environment; CISPR 11:Group 1, Class A | |||
| Tripod Mounting Base | UNC 1/4'-20 Standard Tripod Mounting Thread | |||
| Warranty | 2 years | |||
| Recommended Calibration Period | 2 years (assuming normal operation and aging) | |||
| Optional Lens | ||||
| Tele-photo lens 7° TIX800 4X TELE, TIX800 7C TELE LEN | Tele-photo lens 12° TIX800 2X TELE, TIX800 12C TELE LEN | Wide lens 46° TIX800 2X WIDE, TIX800 46C WIDE LEN | Macro lens 50um TIX800 MACRO, TIX800 50UM MACRO LEN | Macro lens 25um TIX800 MACRO, TIX800 25UM MACRO LEN |
| 5516646 | 5516631 | 5516654 | 5516668 | 5516679 |
| Germanium | Germanium | Germanium | Germanium | Germanium |
| 0.22 mrad | 0.34 mrad | 1.36 mrad | ||
| 8° x 6° | 12.0° x 9.° | 50.0° x 39° | 50 um | 25 um |
| 3 m | 2 m | 1 m | Fixed focus 77.5 mm | Fixed focus 9.4 mm |
| 77.4 mm | 50 mm | 13 mm | ||
Accessories
Fluke Ti885 Thermal Camera (standard lens)
Rechargeable Li-ion Batteries (3 pcs)
Power Adapter
Battery Charger
Lens Cover
USB Cable
HDMI Cable
High-Speed SD Card
Card Reader
Safety Information
Quick Reference Guide
Hand Strap
Neck Strap
Hard Carrying Case
Optional lens
TIX800 4X TELE, TIX800 7C TELE LEN
TIX800 2X TELE, TIX800 12C TELE LEN
TIX800 2X WIDE, TIX800 46C WIDE LEN
TIX800 MACRO, TIX800 50UM MACRO LEN
TIX800 MACRO, TIX800 25UM MACRO LEN